| Keeping
temperature |
Rating voltage |
Rating
Current |
| TH.Th.TC(¡æ) |
(V) |
(A) |
| 35 |
250 |
5 |
10 |
15 |
| 40 |
250 |
5 |
10 |
15 |
| 55 |
250 |
5 |
10 |
15 |
| 60 |
250 |
5 |
10 |
15 |
| 72 |
250 |
5 |
10 |
15 |
| 90 |
250 |
5 |
10 |
15 |
| 90 |
250 |
5 |
10 |
15 |
| 100 |
250 |
5 |
10 |
15 |
| 120 |
250 |
5 |
10 |
15 |
| 130 |
250 |
5 |
10 |
15 |
| 135 |
250 |
5 |
10 |
15 |
| 145 |
250 |
5 |
10 |
15 |
| 150 |
250 |
5 |
10 |
15 |
| 165 |
250 |
5 |
10 |
15 |
| 172 |
250 |
5 |
10 |
15 |
| 200 |
250 |
5 |
10 |
15 |
| 230 |
250 |
5 |
10 |
15 |
Features£º
1¡¢Resist over-heat,cut circuit,prevent calamity,ensure security;
2¡¢Set temperature,high precision,big current load,small
current concussion impact;
3¡¢Fine durability and durative,response quickly to the temperature;
4¡¢Resist liberation,concussion,cut circuit accurately and
don't reset
5¡¢Convenient installation£»
Main purpose£º
RY Hot fuse implement is a non-reduced over-heat protection
component, which changes electric state when it reaches
certain temperature(or action).It is applicable for electric
and electronic facilities whose rating current is smaller
than nominal action current,such as electric stove,electric
iron,hair drier,electric rice cooker and air conditioner
etc.
| Nominal
action temperature |
Off temperature |
Keeping
temperature |
Rating voltage |
Rating
Current |
| TF.TF(¡æ) |
(¡æ) |
TH.Th.TC(¡æ) |
(V) |
(A) |
| 75 |
72 |
40 |
250 |
1 |
2 |
| 80 |
77 |
45 |
250 |
1 |
2 |
| 85 |
80 |
50 |
250 |
1 |
2 |
| 90 |
87 |
60 |
250 |
1 |
2 |
| 95 |
92 |
65 |
250 |
1 |
2 |
| 100 |
98 |
80 |
250 |
1 |
2 |
| 105 |
102 |
85 |
250 |
1 |
2 |
| 110 |
107 |
90 |
250 |
1 |
2 |
| 115 |
113 |
95 |
250 |
1 |
2 |
| 120 |
118 |
100 |
250 |
1 |
2 |
| 123 |
120 |
100 |
250 |
1 |
2 |
| 125 |
122 |
100 |
250 |
1 |
2 |
| 130 |
127 |
105 |
250 |
1 |
2 |
| 135 |
132 |
110 |
250 |
1 |
2 |
| 140 |
137 |
115 |
250 |
1 |
2 |
| 145 |
142 |
120 |
250 |
1 |
2 |
Features£º
1.Resist over-heat,cut circuit,prevent calamity,ensure security;
2.Set temperature,high precision
3.Fine durability and durative,response quickly to the temperature;
4.cut circuit accurately and don't reset
5.High structure precision,fine hermetic property.
6.Convenient installation;
Main purpose£º
RY Hot fuse implement is a non-reduced over-heat protection
component, which changes electric state when it reaches
certain temperature(or action).It is applicable for electric
and electronic facilities whose rating current is smaller
than nominal action current frequenct,smaller than 62HZ
alternating and direct circuit,such as transformer,electric
fan,hair drier,electric stove,electric iron and electronic
loop etc. |